V300 Drives

Brands: ABM
Brands

General Technical Data

  • Rated Power

    0.4~450KW

  • Voltage

    220V/380V

Description

Technical Specifications of V300 Series
Item Specifications
Standard functions Maximum frequency Vector control: 0–3200 Hz
V/F control: 0–5000 Hz
Carrier frequency 0.5–16 kHz The carrier frequency is automatically adjusted based on the load features.
Input frequency resolution Digital setting: 0.01 Hz Analog setting: maximum frequency x 0.025%
Control mode Sensorless flux vector control (SFVC)
Closed-loop vector control (CLVC)
Voltage/Frequency (V/F) control
Startup torque G type: 0.5 Hz/150% (SFVC); 0 Hz/180% (CLVC)
P type: 0.5 Hz/100%
Speed range 1:100 (SFVC)
1:1000 (CLVC)
Speed stability accuracy ± 0.5% (SFVC)
± 0.02% (CLVC)
Torque control accuracy ± 5% (CLVC)
Overload capacity G type: 60s for 150% of the rated current, 3s for 180% of the rated current
P type: 60s for 120% of the rated current, 3s for 150% of the rated current
Torque boost Fixed boost
Customized boost 0.1%–30.0%
V/F curve Straight-line V/F curve
Multi-point V/F curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square)
V/F separation Two types: complete separation , half separation
Ramp mode Straight-line ramp
S-curve ramp
Four groups of acceleration / deceleration time with the range of 0.0–6500.0s
DC braking DC braking frequency: 0.00 Hz to maximum frequency Braking time: 0.0–36.0s Braking action current value: 0.0%–100.0%
Standard functions JOG control JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s
Onboard multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of DI terminal states.
Onboard PID It realizes process-controlled closed loop control system easily.
Auto voltage regulation (AVR) It can keep constant output voltage automatically when the mains voltage changes.
Overvoltage/ Overcurrent stall control The current and voltage are limited automatically during the running process so as to avoid frequent tripping due toovervoltage/overcurrent.
Torque limit and control It can limit the torque automatically and prevent frequent over current tripping during the running process. Torquecontrol can be implemented in the CLVC mode.
Individualized functions High performance Control of asynchronous motor and synchronous motor are implemented through the high-performance current vectorcontrol technology.
Power dip ride through The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.
Rapid current limit It helps to avoid frequent overcurrent faults of the AC drive.
Virtual I/Os Five groups of virtual DI/Dos can realize simple logic control.
Timing control Time range: 0.0–6500.0 minutes
Multi-motor switchover Four motors can be switched over via four groups of motor parameters.
Multiple communication protocols It supports communication via Modbus-RTU.
RUN Running command source Operation panel
Control terminals
Serial communication port
You can perform switchover between these sources in various ways.
Frequency source There are a total of 11 frequency sources, such as digital setting, analog voltage setting, analog current setting, pulsesetting and serial communication port setting.
You can perform switchover between these sources in various ways.
RUN Auxiliary frequency source There are 11 auxiliary frequency sources.
It can implement fine tuning of auxiliary frequency and frequency synthesis.
Input terminal Standard:
6 digit input terminals , DIF(X5) can support high-speed pulse with at maximum 100HZ.
2 analog input (AI) terminals, one of them only supports 0–10 V voltage input and another one supports 0–10 V voltageinput or 4–20 mA current input.
Expanding capacity:
5 DI terminals 1 AI terminal that supports -10–10 V voltage input and also supports
Output terminal Standard:
1 high-speed pulse output terminal (open-collector) that supports 0–100 kHz square wave signal output 1 digital output(DO) terminal 1 relay output terminal 1 analog output (AO) terminal that supports 0–20 mA current output or 0–10 Vvoltage output Expanding capacity: 1 DO terminal 1 relay output terminal 1 AO terminal that supports 0–20 mA currentoutput or 0–10 V voltage output
Display and operationpanel display It displays the parameters.
Key locking and function selection It can lock the keys partially or completely and define the function range of some keys so as to prevent mis-function.
the Protection mode Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltageprotection, undervoltage protection, overheat protection and overload protection
Environment Installation location Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt.
Altitude Lower than 1000m
Ambient temperature -10°C to +40°C (de-rated if the ambient temperature is between 40°C and 50°C)
Humidity Less than 95%RH, without condensing
Vibration Less than 5.9 m/s2 (0.6 g)
Storage temperature -20°C to +60°C
IP level IP20
Pollution degree PD2
Power distribution system TN , TT

Model designation

V300

V300-0.4G/0.75LS1(S2) V300-0.75G/1.5LS1(S2) V300-1.5G/2.2LS1(S2) V300-2.2G/3.0LS1(S2) V300-4.0G/5.5LS1(S2) V300-5.5G/7.5LS1(S2) V300-7.5G/11LS1(S2) V300-11G/15LS1(S2) V300-0.75G/1.5LT4B V300-1.5G/2.2LT4B V300-2.2G/3.0LT4B V300-4.0GT4B V300-4.0G/5.5LT4B V300-5.5G/7.5LT4B V300-7.5G/11LT4B V300-11GT4B V300-11G/15LT4B V300-15G/18.5LT4B V300-18.5G/22LT4B V300-22GT4 V300-22G/30LT4 V300-30G/37LT4 V300-37G/45LT4 V300-45G/55LT4 V300-55G/75LT4 V300-75G/93LT4 V300-93G/110LT4 V300-110G/132LT4 V300-132G/160LT4 V300-160G/185LT4 V300-185G/200LT4 V300-200G/220LT4 V300-220G/250LT4 V300-250G/280LT4 V300-280G/315LT4 V300-315G/355LT4 V300-350G/400LT4 V300-400G/450LT4 V300-450G/500LT4
Brands
ABM (44)
HAVAT (2)
HAWARA (9)
KASUTO (3)